Performance Indicators

2020-06-30

# 182

KhNPP 1
Electricity production
 
 per day: 19.83 mln.kW*h 
 
 since the beginning of month: 614.72 mln. kW*h 
 
 since the beginning of quarter: 1841.17 mln. kW*h 
 
 since the beginning of year: 1841.17 mln. kW*h 
 
 electricity utilization for auxiliaries: 5.58 % 
 
General characteristics
 
 
 Hours worked: 78.5 ef. days 
 
 Campaign: 356.6 ef. days 
 
 Performance factor (net)of the unit: 29.86 % 
 
 Electrical power (average daily): 826.32 MW 
 
 The temperature of circulating water at the inlet:  8.7  o, C 
 
KhNPP 2
Electricity production
 
 per day: 21.73 mln.kW*h 
 
 since the beginning of month: 621.54 mln. kW*h 
 
 since the beginning of quarter: 1709.75 mln. kW*h 
 
 since the beginning of year: 3922.58 mln. kW*h 
 
 electricity utilization for auxiliaries: 5.09 % 
 
General characteristics
 
 
 Hours worked: 213.8 ef. days 
 
 Campaign: 220 ef. days 
 
 Performance factor (net)of the unit: 30.5 % 
 
 Electrical power (average daily): 905.58 MW 
 
 The temperature of circulating water at the inlet:  8.2  o, C 
 
Operating mode of heating system
 
  direct  reverse  
 temperature : 6751 o, C 
 
 t of outside air: 21.1 o, C 
 
Emission in ventiduct
 
 long-lived nuclides:  3.15*10+04 Bq /day   MPE*  1,00*10+09  Bq /day 
 
 short-lived nuclides:  . Bq /day   MPE:  not regulated  Bq /day 
 
 Inert gases:  3.18*10+10 Bq /day   MPE:   4,60*10+13  Bq /day 
 
 Iodine:  3.15*10+04 Bq /day   MPE:   4,60*10+09  Bq /day 
 * - maximum permissible emission 
Water utilization
 
 on the town: 7357 m3 
 
 on construction yard: 8 m3 
 
 on industrial site: 261 m3 
 

2020-06-29

# 181

KhNPP 1
Electricity production
 
 per day: 19.82 mln.kW*h 
 
 since the beginning of month: 594.89 mln. kW*h 
 
 since the beginning of quarter: 1821.33 mln. kW*h 
 
 since the beginning of year: 1821.33 mln. kW*h 
 
 electricity utilization for auxiliaries: 5.53 % 
 
General characteristics
 
 
 Hours worked: 77.9 ef. days 
 
 Campaign: 356.6 ef. days 
 
 Performance factor (net)of the unit: 29.7 % 
 
 Electrical power (average daily): 825.72 MW 
 
 The temperature of circulating water at the inlet:  8.7  o, C 
 
KhNPP 2
Electricity production
 
 per day: 21.72 mln.kW*h 
 
 since the beginning of month: 599.8 mln. kW*h 
 
 since the beginning of quarter: 1688.01 mln. kW*h 
 
 since the beginning of year: 3900.85 mln. kW*h 
 
 electricity utilization for auxiliaries: 5.15 % 
 
General characteristics
 
 
 Hours worked: 213.2 ef. days 
 
 Campaign: 220 ef. days 
 
 Performance factor (net)of the unit: 30.3 % 
 
 Electrical power (average daily): 905.16 MW 
 
 The temperature of circulating water at the inlet:  8.2  o, C 
 
Operating mode of heating system
 
  direct  reverse  
 temperature : 6650 o, C 
 
 t of outside air: 24.6 o, C 
 
Emission in ventiduct
 
 long-lived nuclides:  3.19*10+04 Bq /day   MPE*  1,00*10+09  Bq /day 
 
 short-lived nuclides:  . Bq /day   MPE:  not regulated  Bq /day 
 
 Inert gases:  3.05*10+10 Bq /day   MPE:   4,60*10+13  Bq /day 
 
 Iodine:  3.19*10+04 Bq /day   MPE:   4,60*10+09  Bq /day 
 * - maximum permissible emission 
Water utilization
 
 on the town: 6879 m3 
 
 on construction yard: . m3 
 
 on industrial site: . m3 
 

2020-06-28

# 180

KhNPP 1
Electricity production
 
 per day: 19.83 mln.kW*h 
 
 since the beginning of month: 575.08 mln. kW*h 
 
 since the beginning of quarter: 1801.52 mln. kW*h 
 
 since the beginning of year: 1801.52 mln. kW*h 
 
 electricity utilization for auxiliaries: 5.54 % 
 
General characteristics
 
 
 Hours worked: 76.8 ef. days 
 
 Campaign: 356.6 ef. days 
 
 Performance factor (net)of the unit: 29.86 % 
 
 Electrical power (average daily): 826.44 MW 
 
 The temperature of circulating water at the inlet:  8.7  o, C 
 
KhNPP 2
Electricity production
 
 per day: 21.75 mln.kW*h 
 
 since the beginning of month: 578.08 mln. kW*h 
 
 since the beginning of quarter: 1666.29 mln. kW*h 
 
 since the beginning of year: 3879.13 mln. kW*h 
 
 electricity utilization for auxiliaries: 5.13 % 
 
General characteristics
 
 
 Hours worked: 212 ef. days 
 
 Campaign: 220 ef. days 
 
 Performance factor (net)of the unit: 30.41 % 
 
 Electrical power (average daily): 906.12 MW 
 
 The temperature of circulating water at the inlet:  8.2  o, C 
 
Operating mode of heating system
 
  direct  reverse  
 temperature : 6650 o, C 
 
 t of outside air: 22.7 o, C 
 
Emission in ventiduct
 
 long-lived nuclides:  3.18*10+04 Bq /day   MPE*  1,00*10+09  Bq /day 
 
 short-lived nuclides:  . Bq /day   MPE:  not regulated  Bq /day 
 
 Inert gases:  3.07*10+10 Bq /day   MPE:   4,60*10+13  Bq /day 
 
 Iodine:  3.18*10+04 Bq /day   MPE:   4,60*10+09  Bq /day 
 * - maximum permissible emission 
Water utilization
 
 on the town: 7036 m3 
 
 on construction yard: 0 m3 
 
 on industrial site: 0 m3 
 

2020-06-27

# 179

KhNPP 1
Electricity production
 
 per day: 19.84 mln.kW*h 
 
 since the beginning of month: 555.24 mln. kW*h 
 
 since the beginning of quarter: 1781.68 mln. kW*h 
 
 since the beginning of year: 1781.68 mln. kW*h 
 
 electricity utilization for auxiliaries: 5.53 % 
 
General characteristics
 
 
 Hours worked: 75.9 ef. days 
 
 Campaign: 356.6 ef. days 
 
 Performance factor (net)of the unit: 29.97 % 
 
 Electrical power (average daily): 826.8 MW 
 
 The temperature of circulating water at the inlet:  8.7  o, C 
 
KhNPP 2
Electricity production
 
 per day: 21.72 mln.kW*h 
 
 since the beginning of month: 556.33 mln. kW*h 
 
 since the beginning of quarter: 1644.54 mln. kW*h 
 
 since the beginning of year: 3857.38 mln. kW*h 
 
 electricity utilization for auxiliaries: 5.13 % 
 
General characteristics
 
 
 Hours worked: 211 ef. days 
 
 Campaign: 220 ef. days 
 
 Performance factor (net)of the unit: 30.5 % 
 
 Electrical power (average daily): 904.98 MW 
 
 The temperature of circulating water at the inlet:  8.2  o, C 
 
Operating mode of heating system
 
  direct  reverse  
 temperature : 6650 o, C 
 
 t of outside air: 23.8 o, C 
 
Emission in ventiduct
 
 long-lived nuclides:  3.16*10+04 Bq /day   MPE*  1,00*10+09  Bq /day 
 
 short-lived nuclides:  . Bq /day   MPE:  not regulated  Bq /day 
 
 Inert gases:  2.94*10+10 Bq /day   MPE:   4,60*10+13  Bq /day 
 
 Iodine:  3.16*10+04 Bq /day   MPE:   4,60*10+09  Bq /day 
 * - maximum permissible emission 
Water utilization
 
 on the town: 7247 m3 
 
 on construction yard: . m3 
 
 on industrial site: . m3 
 

2020-06-26

# 178

KhNPP 1
Electricity production
 
 per day: 19.78 mln.kW*h 
 
 since the beginning of month: 535.4 mln. kW*h 
 
 since the beginning of quarter: 1761.84 mln. kW*h 
 
 since the beginning of year: 1761.84 mln. kW*h 
 
 electricity utilization for auxiliaries: 5.56 % 
 
General characteristics
 
 
 Hours worked: 75 ef. days 
 
 Campaign: 356.6 ef. days 
 
 Performance factor (net)of the unit: 29.9 % 
 
 Electrical power (average daily): 824.34 MW 
 
 The temperature of circulating water at the inlet:  8.7  o, C 
 
KhNPP 2
Electricity production
 
 per day: 21.74 mln.kW*h 
 
 since the beginning of month: 534.61 mln. kW*h 
 
 since the beginning of quarter: 1622.82 mln. kW*h 
 
 since the beginning of year: 3835.66 mln. kW*h 
 
 electricity utilization for auxiliaries: 5.08 % 
 
General characteristics
 
 
 Hours worked: 210 ef. days 
 
 Campaign: 220 ef. days 
 
 Performance factor (net)of the unit: 30.6 % 
 
 Electrical power (average daily): 905.82 MW 
 
 The temperature of circulating water at the inlet:  8.2  o, C 
 
Operating mode of heating system
 
  direct  reverse  
 temperature : 6753 o, C 
 
 t of outside air: 23.6 o, C 
 
Emission in ventiduct
 
 long-lived nuclides:  3.22*10+04 Bq /day   MPE*  1,00*10+09  Bq /day 
 
 short-lived nuclides:  . Bq /day   MPE:  not regulated  Bq /day 
 
 Inert gases:  3.45*10+10 Bq /day   MPE:   4,60*10+13  Bq /day 
 
 Iodine:  3.22*10+04 Bq /day   MPE:   4,60*10+09  Bq /day 
 * - maximum permissible emission 
Water utilization
 
 on the town: 6989 m3 
 
 on construction yard: 34 m3 
 
 on industrial site: 397 m3 
 

2020-06-25

# 177

KhNPP 1
Electricity production
 
 per day: 19.84 mln.kW*h 
 
 since the beginning of month: 515.61 mln. kW*h 
 
 since the beginning of quarter: 1742.05 mln. kW*h 
 
 since the beginning of year: 1742.05 mln. kW*h 
 
 electricity utilization for auxiliaries: 5.6 % 
 
General characteristics
 
 
 Hours worked: 74.2 ef. days 
 
 Campaign: 356.6 ef. days 
 
 Performance factor (net)of the unit: 30.07 % 
 
 Electrical power (average daily): 826.56 MW 
 
 The temperature of circulating water at the inlet:  8.7  o, C 
 
KhNPP 2
Electricity production
 
 per day: 21.71 mln.kW*h 
 
 since the beginning of month: 512.87 mln. kW*h 
 
 since the beginning of quarter: 1601.08 mln. kW*h 
 
 since the beginning of year: 3813.92 mln. kW*h 
 
 electricity utilization for auxiliaries: 5.08 % 
 
General characteristics
 
 
 Hours worked: 209.2 ef. days 
 
 Campaign: 220 ef. days 
 
 Performance factor (net)of the unit: 30.73 % 
 
 Electrical power (average daily): 904.62 MW 
 
 The temperature of circulating water at the inlet:  8.2  o, C 
 
Operating mode of heating system
 
  direct  reverse  
 temperature : 6650 o, C 
 
 t of outside air: 22.5 o, C 
 
Emission in ventiduct
 
 long-lived nuclides:  3.22*10+04 Bq /day   MPE*  1,00*10+09  Bq /day 
 
 short-lived nuclides:  . Bq /day   MPE:  not regulated  Bq /day 
 
 Inert gases:  2.99*10+10 Bq /day   MPE:   4,60*10+13  Bq /day 
 
 Iodine:  3.22*10+04 Bq /day   MPE:   4,60*10+09  Bq /day 
 * - maximum permissible emission 
Water utilization
 
 on the town: 7093 m3 
 
 on construction yard: 35 m3 
 
 on industrial site: 387 m3 
 

2020-06-24

# 176

KhNPP 1
Electricity production
 
 per day: 19.82 mln.kW*h 
 
 since the beginning of month: 495.78 mln. kW*h 
 
 since the beginning of quarter: 1722.22 mln. kW*h 
 
 since the beginning of year: 1722.22 mln. kW*h 
 
 electricity utilization for auxiliaries: 5.52 % 
 
General characteristics
 
 
 Hours worked: 73.3 ef. days 
 
 Campaign: 356.6 ef. days 
 
 Performance factor (net)of the unit: 30.04 % 
 
 Electrical power (average daily): 825.72 MW 
 
 The temperature of circulating water at the inlet:  8.7  o, C 
 
KhNPP 2
Electricity production
 
 per day: 21.72 mln.kW*h 
 
 since the beginning of month: 491.16 mln. kW*h 
 
 since the beginning of quarter: 1579.37 mln. kW*h 
 
 since the beginning of year: 3792.21 mln. kW*h 
 
 electricity utilization for auxiliaries: 5.14 % 
 
General characteristics
 
 
 Hours worked: 208.2 ef. days 
 
 Campaign: 220 ef. days 
 
 Performance factor (net)of the unit: 30.8 % 
 
 Electrical power (average daily): 905.1 MW 
 
 The temperature of circulating water at the inlet:  8.2  o, C 
 
Operating mode of heating system
 
  direct  reverse  
 temperature : 8750 o, C 
 
 t of outside air: 20.9 o, C 
 
Emission in ventiduct
 
 long-lived nuclides:  3.23*10+04 Bq /day   MPE*  1,00*10+09  Bq /day 
 
 short-lived nuclides:  . Bq /day   MPE:  not regulated  Bq /day 
 
 Inert gases:  3.04*10+10 Bq /day   MPE:   4,60*10+13  Bq /day 
 
 Iodine:  3.23*10+04 Bq /day   MPE:   4,60*10+09  Bq /day 
 * - maximum permissible emission 
Water utilization
 
 on the town: 7003 m3 
 
 on construction yard: 27 m3 
 
 on industrial site: 387 m3 
 

2020-06-23

# 175

KhNPP 1
Electricity production
 
 per day: 19.83 mln.kW*h 
 
 since the beginning of month: 475.96 mln. kW*h 
 
 since the beginning of quarter: 1702.4 mln. kW*h 
 
 since the beginning of year: 1702.4 mln. kW*h 
 
 electricity utilization for auxiliaries: 5.5 % 
 
General characteristics
 
 
 Hours worked: 72.7 ef. days 
 
 Campaign: 356.6 ef. days 
 
 Performance factor (net)of the unit: 29.96 % 
 
 Electrical power (average daily): 826.38 MW 
 
 The temperature of circulating water at the inlet:  8.7  o, C 
 
KhNPP 2
Electricity production
 
 per day: 21.71 mln.kW*h 
 
 since the beginning of month: 469.44 mln. kW*h 
 
 since the beginning of quarter: 1557.65 mln. kW*h 
 
 since the beginning of year: 3770.49 mln. kW*h 
 
 electricity utilization for auxiliaries: 5.18 % 
 
General characteristics
 
 
 Hours worked: 207.5 ef. days 
 
 Campaign: 220 ef. days 
 
 Performance factor (net)of the unit: 30.58 % 
 
 Electrical power (average daily): 904.38 MW 
 
 The temperature of circulating water at the inlet:  8.2  o, C 
 
Operating mode of heating system
 
  direct  reverse  
 temperature : 7056 o, C 
 
 t of outside air: 19.9 o, C 
 
Emission in ventiduct
 
 long-lived nuclides:  3.21*10+04 Bq /day   MPE*  1,00*10+09  Bq /day 
 
 short-lived nuclides:  . Bq /day   MPE:  not regulated  Bq /day 
 
 Inert gases:  2.98*10+10 Bq /day   MPE:   4,60*10+13  Bq /day 
 
 Iodine:  3.21*10+04 Bq /day   MPE:   4,60*10+09  Bq /day 
 * - maximum permissible emission 
Water utilization
 
 on the town: 7409 m3 
 
 on construction yard: 35 m3 
 
 on industrial site: 400 m3 
 

2020-06-22

# 174

KhNPP 1
Electricity production
 
 per day: 19.83 mln.kW*h 
 
 since the beginning of month: 456.13 mln. kW*h 
 
 since the beginning of quarter: 1682.57 mln. kW*h 
 
 since the beginning of year: 1682.57 mln. kW*h 
 
 electricity utilization for auxiliaries: 5.58 % 
 
General characteristics
 
 
 Hours worked: 71.6 ef. days 
 
 Campaign: 356.6 ef. days 
 
 Performance factor (net)of the unit: 30 % 
 
 Electrical power (average daily): 826.14 MW 
 
 The temperature of circulating water at the inlet:  8.7  o, C 
 
KhNPP 2
Electricity production
 
 per day: 21.74 mln.kW*h 
 
 since the beginning of month: 447.74 mln. kW*h 
 
 since the beginning of quarter: 1535.94 mln. kW*h 
 
 since the beginning of year: 3748.78 mln. kW*h 
 
 electricity utilization for auxiliaries: 5.03 % 
 
General characteristics
 
 
 Hours worked: 206.3 ef. days 
 
 Campaign: 220 ef. days 
 
 Performance factor (net)of the unit: 30.82 % 
 
 Electrical power (average daily): 905.94 MW 
 
 The temperature of circulating water at the inlet:  8.2  o, C 
 
Operating mode of heating system
 
  direct  reverse  
 temperature : 6851 o, C 
 
 t of outside air: 21.5 o, C 
 
Emission in ventiduct
 
 long-lived nuclides:  3.20*10+04 Bq /day   MPE*  1,00*10+09  Bq /day 
 
 short-lived nuclides:  . Bq /day   MPE:  not regulated  Bq /day 
 
 Inert gases:  3.08*10+10 Bq /day   MPE:   4,60*10+13  Bq /day 
 
 Iodine:  3.20*10+04 Bq /day   MPE:   4,60*10+09  Bq /day 
 * - maximum permissible emission 
Water utilization
 
 on the town: 7217 m3 
 
 on construction yard: 18 m3 
 
 on industrial site: 303 m3 
 

2020-06-21

# 173

KhNPP 1
Electricity production
 
 per day: 19.82 mln.kW*h 
 
 since the beginning of month: 436.3 mln. kW*h 
 
 since the beginning of quarter: 1662.74 mln. kW*h 
 
 since the beginning of year: 1662.74 mln. kW*h 
 
 electricity utilization for auxiliaries: 5.51 % 
 
General characteristics
 
 
 Hours worked: 70.7 ef. days 
 
 Campaign: 356.6 ef. days 
 
 Performance factor (net)of the unit: 29.97 % 
 
 Electrical power (average daily): 825.72 MW 
 
 The temperature of circulating water at the inlet:  8.7  o, C 
 
KhNPP 2
Electricity production
 
 per day: 21.68 mln.kW*h 
 
 since the beginning of month: 425.99 mln. kW*h 
 
 since the beginning of quarter: 1514.2 mln. kW*h 
 
 since the beginning of year: 3727.04 mln. kW*h 
 
 electricity utilization for auxiliaries: 4.99 % 
 
General characteristics
 
 
 Hours worked: 205.4 ef. days 
 
 Campaign: 220 ef. days 
 
 Performance factor (net)of the unit: 30.75 % 
 
 Electrical power (average daily): 903.18 MW 
 
 The temperature of circulating water at the inlet:  8.2  o, C 
 
Operating mode of heating system
 
  direct  reverse  
 temperature : 6850 o, C 
 
 t of outside air: 20.4 o, C 
 
Emission in ventiduct
 
 long-lived nuclides:  3.12*10+04 Bq /day   MPE*  1,00*10+09  Bq /day 
 
 short-lived nuclides:  . Bq /day   MPE:  not regulated  Bq /day 
 
 Inert gases:  3.07*10+10 Bq /day   MPE:   4,60*10+13  Bq /day 
 
 Iodine:  3.12*10+04 Bq /day   MPE:   4,60*10+09  Bq /day 
 * - maximum permissible emission 
Water utilization
 
 on the town: 7230 m3 
 
 on construction yard: 0 m3 
 
 on industrial site: 0 m3 
 

2020-06-20

# 172

KhNPP 1
Electricity production
 
 per day: 19.06 mln.kW*h 
 
 since the beginning of month: 416.48 mln. kW*h 
 
 since the beginning of quarter: 1642.92 mln. kW*h 
 
 since the beginning of year: 1642.92 mln. kW*h 
 
 electricity utilization for auxiliaries: 5.76 % 
 
General characteristics
 
 
 Hours worked: 70.1 ef. days 
 
 Campaign: 356.6 ef. days 
 
 Performance factor (net)of the unit: 29.5 % 
 
 Electrical power (average daily): 794.16 MW 
 
 The temperature of circulating water at the inlet:  8.7  o, C 
 
KhNPP 2
Electricity production
 
 per day: 20.97 mln.kW*h 
 
 since the beginning of month: 404.32 mln. kW*h 
 
 since the beginning of quarter: 1492.53 mln. kW*h 
 
 since the beginning of year: 3705.36 mln. kW*h 
 
 electricity utilization for auxiliaries: 5.12 % 
 
General characteristics
 
 
 Hours worked: 204.7 ef. days 
 
 Campaign: 220 ef. days 
 
 Performance factor (net)of the unit: 30.3 % 
 
 Electrical power (average daily): 873.6 MW 
 
 The temperature of circulating water at the inlet:  8.2  o, C 
 
Operating mode of heating system
 
  direct  reverse  
 temperature : 6851 o, C 
 
 t of outside air: 22.2 o, C 
 
Emission in ventiduct
 
 long-lived nuclides:  3.16*10+04 Bq /day   MPE*  1,00*10+09  Bq /day 
 
 short-lived nuclides:  . Bq /day   MPE:  not regulated  Bq /day 
 
 Inert gases:  2.92*10+10 Bq /day   MPE:   4,60*10+13  Bq /day 
 
 Iodine:  3.16*10+04 Bq /day   MPE:   4,60*10+09  Bq /day 
 * - maximum permissible emission 
Water utilization
 
 on the town: 7302 m3 
 
 on construction yard: . m3 
 
 on industrial site: . m3 
 

2020-06-19

# 171

KhNPP 1
Electricity production
 
 per day: 18.83 mln.kW*h 
 
 since the beginning of month: 397.42 mln. kW*h 
 
 since the beginning of quarter: 1623.86 mln. kW*h 
 
 since the beginning of year: 1623.86 mln. kW*h 
 
 electricity utilization for auxiliaries: 5.81 % 
 
General characteristics
 
 
 Hours worked: 69.1 ef. days 
 
 Campaign: 356.6 ef. days 
 
 Performance factor (net)of the unit: 29.2 % 
 
 Electrical power (average daily): 784.56 MW 
 
 The temperature of circulating water at the inlet:  8.7  o, C 
 
KhNPP 2
Electricity production
 
 per day: 20.77 mln.kW*h 
 
 since the beginning of month: 383.35 mln. kW*h 
 
 since the beginning of quarter: 1471.56 mln. kW*h 
 
 since the beginning of year: 3684.4 mln. kW*h 
 
 electricity utilization for auxiliaries: 5.26 % 
 
General characteristics
 
 
 Hours worked: 203.6 ef. days 
 
 Campaign: 220 ef. days 
 
 Performance factor (net)of the unit: 30.2 % 
 
 Electrical power (average daily): 865.32 MW 
 
 The temperature of circulating water at the inlet:  8.2  o, C 
 
Operating mode of heating system
 
  direct  reverse  
 temperature : 6851 o, C 
 
 t of outside air: 22 o, C 
 
Emission in ventiduct
 
 long-lived nuclides:  3.20*10+04 Bq /day   MPE*  1,00*10+09  Bq /day 
 
 short-lived nuclides:  . Bq /day   MPE:  not regulated  Bq /day 
 
 Inert gases:  3.02*10+10 Bq /day   MPE:   4,60*10+13  Bq /day 
 
 Iodine:  3.20*10+04 Bq /day   MPE:   4,60*10+09  Bq /day 
 * - maximum permissible emission 
Water utilization
 
 on the town: 7372 m3 
 
 on construction yard: 43 m3 
 
 on industrial site: 487 m3 
 

2020-06-18

# 170

KhNPP 1
Electricity production
 
 per day: 19.25 mln.kW*h 
 
 since the beginning of month: 378.59 mln. kW*h 
 
 since the beginning of quarter: 1605.03 mln. kW*h 
 
 since the beginning of year: 1605.03 mln. kW*h 
 
 electricity utilization for auxiliaries: 5.7 % 
 
General characteristics
 
 
 Hours worked: 68.4 ef. days 
 
 Campaign: 356.6 ef. days 
 
 Performance factor (net)of the unit: 29.69 % 
 
 Electrical power (average daily): 802.26 MW 
 
 The temperature of circulating water at the inlet:  8.7  o, C 
 
KhNPP 2
Electricity production
 
 per day: 20.74 mln.kW*h 
 
 since the beginning of month: 362.58 mln. kW*h 
 
 since the beginning of quarter: 1450.79 mln. kW*h 
 
 since the beginning of year: 3663.63 mln. kW*h 
 
 electricity utilization for auxiliaries: 5.25 % 
 
General characteristics
 
 
 Hours worked: 202.9 ef. days 
 
 Campaign: 220 ef. days 
 
 Performance factor (net)of the unit: 30.11 % 
 
 Electrical power (average daily): 864.12 MW 
 
 The temperature of circulating water at the inlet:  8.2  o, C 
 
Operating mode of heating system
 
  direct  reverse  
 temperature : 6851 o, C 
 
 t of outside air: 21.7 o, C 
 
Emission in ventiduct
 
 long-lived nuclides:  3.23*10+04 Bq /day   MPE*  1,00*10+09  Bq /day 
 
 short-lived nuclides:  . Bq /day   MPE:  not regulated  Bq /day 
 
 Inert gases:  2.98*10+10 Bq /day   MPE:   4,60*10+13  Bq /day 
 
 Iodine:  3.23*10+04 Bq /day   MPE:   4,60*10+09  Bq /day 
 * - maximum permissible emission 
Water utilization
 
 on the town: 7234 m3 
 
 on construction yard: 17 m3 
 
 on industrial site: 478 m3 
 

2020-06-17

# 169

KhNPP 1
Electricity production
 
 per day: 21.23 mln.kW*h 
 
 since the beginning of month: 359.34 mln. kW*h 
 
 since the beginning of quarter: 1585.78 mln. kW*h 
 
 since the beginning of year: 1585.78 mln. kW*h 
 
 electricity utilization for auxiliaries: 5.14 % 
 
General characteristics
 
 
 Hours worked: 67.4 ef. days 
 
 Campaign: 356.6 ef. days 
 
 Performance factor (net)of the unit: 30.7 % 
 
 Electrical power (average daily): 884.58 MW 
 
 The temperature of circulating water at the inlet:  8.7  o, C 
 
KhNPP 2
Electricity production
 
 per day: 20.73 mln.kW*h 
 
 since the beginning of month: 341.84 mln. kW*h 
 
 since the beginning of quarter: 1430.05 mln. kW*h 
 
 since the beginning of year: 3642.89 mln. kW*h 
 
 electricity utilization for auxiliaries: 5.19 % 
 
General characteristics
 
 
 Hours worked: 201.8 ef. days 
 
 Campaign: 220 ef. days 
 
 Performance factor (net)of the unit: 30.1 % 
 
 Electrical power (average daily): 863.94 MW 
 
 The temperature of circulating water at the inlet:  8.2  o, C 
 
Operating mode of heating system
 
  direct  reverse  
 temperature : 6848 o, C 
 
 t of outside air: 20 o, C 
 
Emission in ventiduct
 
 long-lived nuclides:  3.24*10+04 Bq /day   MPE*  1,00*10+09  Bq /day 
 
 short-lived nuclides:  . Bq /day   MPE:  not regulated  Bq /day 
 
 Inert gases:  3.07*10+10 Bq /day   MPE:   4,60*10+13  Bq /day 
 
 Iodine:  3.24*10+04 Bq /day   MPE:   4,60*10+09  Bq /day 
 * - maximum permissible emission 
Water utilization
 
 on the town: 7321 m3 
 
 on construction yard: 59 m3 
 
 on industrial site: 476 m3 
 

2020-06-16

# 168

KhNPP 1
Electricity production
 
 per day: 21.25 mln.kW*h 
 
 since the beginning of month: 338.11 mln. kW*h 
 
 since the beginning of quarter: 1564.55 mln. kW*h 
 
 since the beginning of year: 1564.55 mln. kW*h 
 
 electricity utilization for auxiliaries: 5.15 % 
 
General characteristics
 
 
 Hours worked: 66.5 ef. days 
 
 Campaign: 356.6 ef. days 
 
 Performance factor (net)of the unit: 30.7 % 
 
 Electrical power (average daily): 885.42 MW 
 
 The temperature of circulating water at the inlet:  8.7  o, C 
 
KhNPP 2
Electricity production
 
 per day: 20.77 mln.kW*h 
 
 since the beginning of month: 321.11 mln. kW*h 
 
 since the beginning of quarter: 1409.32 mln. kW*h 
 
 since the beginning of year: 3622.16 mln. kW*h 
 
 electricity utilization for auxiliaries: 5.24 % 
 
General characteristics
 
 
 Hours worked: 200.8 ef. days 
 
 Campaign: 220 ef. days 
 
 Performance factor (net)of the unit: 30.1 % 
 
 Electrical power (average daily): 865.32 MW 
 
 The temperature of circulating water at the inlet:  8.2  o, C 
 
Operating mode of heating system
 
  direct  reverse  
 temperature : 6750 o, C 
 
 t of outside air: 19.7 o, C 
 
Emission in ventiduct
 
 long-lived nuclides:  3.24*10+04 Bq /day   MPE*  1,00*10+09  Bq /day 
 
 short-lived nuclides:  . Bq /day   MPE:  not regulated  Bq /day 
 
 Inert gases:  3.07*10+10 Bq /day   MPE:   4,60*10+13  Bq /day 
 
 Iodine:  3.24*10+04 Bq /day   MPE:   4,60*10+09  Bq /day 
 * - maximum permissible emission 
Water utilization
 
 on the town: 7418 m3 
 
 on construction yard: 91 m3 
 
 on industrial site: 455 m3 
 

2020-06-15

# 167

KhNPP 1
Electricity production
 
 per day: 21.26 mln.kW*h 
 
 since the beginning of month: 316.86 mln. kW*h 
 
 since the beginning of quarter: 1543.3 mln. kW*h 
 
 since the beginning of year: 1543.3 mln. kW*h 
 
 electricity utilization for auxiliaries: 5.13 % 
 
General characteristics
 
 
 Hours worked: 65.6 ef. days 
 
 Campaign: 356.6 ef. days 
 
 Performance factor (net)of the unit: 30.72 % 
 
 Electrical power (average daily): 885.84 MW 
 
 The temperature of circulating water at the inlet:  8.7  o, C 
 
KhNPP 2
Electricity production
 
 per day: 20.71 mln.kW*h 
 
 since the beginning of month: 300.34 mln. kW*h 
 
 since the beginning of quarter: 1388.55 mln. kW*h 
 
 since the beginning of year: 3601.39 mln. kW*h 
 
 electricity utilization for auxiliaries: 5.24 % 
 
General characteristics
 
 
 Hours worked: 200 ef. days 
 
 Campaign: 220 ef. days 
 
 Performance factor (net)of the unit: 30.07 % 
 
 Electrical power (average daily): 863.1 MW 
 
 The temperature of circulating water at the inlet:  8.2  o, C 
 
Operating mode of heating system
 
  direct  reverse  
 temperature : 6750 o, C 
 
 t of outside air: 18.2 o, C 
 
Emission in ventiduct
 
 long-lived nuclides:  3.23*10+04 Bq /day   MPE*  1,00*10+09  Bq /day 
 
 short-lived nuclides:  . Bq /day   MPE:  not regulated  Bq /day 
 
 Inert gases:  3.04*10+10 Bq /day   MPE:   4,60*10+13  Bq /day 
 
 Iodine:  3.23*10+04 Bq /day   MPE:   4,60*10+09  Bq /day 
 * - maximum permissible emission 
Water utilization
 
 on the town: 7156 m3 
 
 on construction yard: 67 m3 
 
 on industrial site: 336 m3 
 

2020-06-14

# 166

KhNPP 1
Electricity production
 
 per day: 21.24 mln.kW*h 
 
 since the beginning of month: 295.6 mln. kW*h 
 
 since the beginning of quarter: 1522.04 mln. kW*h 
 
 since the beginning of year: 1522.04 mln. kW*h 
 
 electricity utilization for auxiliaries: 5.15 % 
 
General characteristics
 
 
 Hours worked: 64.7 ef. days 
 
 Campaign: 356.6 ef. days 
 
 Performance factor (net)of the unit: 30.7 % 
 
 Electrical power (average daily): 885.12 MW 
 
 The temperature of circulating water at the inlet:  8.7  o, C 
 
KhNPP 2
Electricity production
 
 per day: 20.74 mln.kW*h 
 
 since the beginning of month: 279.63 mln. kW*h 
 
 since the beginning of quarter: 1367.84 mln. kW*h 
 
 since the beginning of year: 3580.67 mln. kW*h 
 
 electricity utilization for auxiliaries: 5.22 % 
 
General characteristics
 
 
 Hours worked: 199 ef. days 
 
 Campaign: 220 ef. days 
 
 Performance factor (net)of the unit: 30.1 % 
 
 Electrical power (average daily): 864.24 MW 
 
 The temperature of circulating water at the inlet:  8.2  o, C 
 
Operating mode of heating system
 
  direct  reverse  
 temperature : 6852 o, C 
 
 t of outside air: 17.7 o, C 
 
Emission in ventiduct
 
 long-lived nuclides:  3.22*10+04 Bq /day   MPE*  1,00*10+09  Bq /day 
 
 short-lived nuclides:  . Bq /day   MPE:  not regulated  Bq /day 
 
 Inert gases:  3.03*10+10 Bq /day   MPE:   4,60*10+13  Bq /day 
 
 Iodine:  3.22*10+04 Bq /day   MPE:   4,60*10+09  Bq /day 
 * - maximum permissible emission 
Water utilization
 
 on the town: 7456 m3 
 
 on construction yard: . m3 
 
 on industrial site: . m3 
 

2020-06-13

# 165

KhNPP 1
Electricity production
 
 per day: 21.25 mln.kW*h 
 
 since the beginning of month: 274.35 mln. kW*h 
 
 since the beginning of quarter: 1500.8 mln. kW*h 
 
 since the beginning of year: 1500.8 mln. kW*h 
 
 electricity utilization for auxiliaries: 5.17 % 
 
General characteristics
 
 
 Hours worked: 64 ef. days 
 
 Campaign: 356.6 ef. days 
 
 Performance factor (net)of the unit: 30.7 % 
 
 Electrical power (average daily): 885.6 MW 
 
 The temperature of circulating water at the inlet:  8.7  o, C 
 
KhNPP 2
Electricity production
 
 per day: 20.72 mln.kW*h 
 
 since the beginning of month: 258.89 mln. kW*h 
 
 since the beginning of quarter: 1347.09 mln. kW*h 
 
 since the beginning of year: 3559.93 mln. kW*h 
 
 electricity utilization for auxiliaries: 5.21 % 
 
General characteristics
 
 
 Hours worked: 198.3 ef. days 
 
 Campaign: 230 ef. days 
 
 Performance factor (net)of the unit: 30.07 % 
 
 Electrical power (average daily): 863.52 MW 
 
 The temperature of circulating water at the inlet:  8.2  o, C 
 
Operating mode of heating system
 
  direct  reverse  
 temperature : 6852 o, C 
 
 t of outside air: 23.6 o, C 
 
Emission in ventiduct
 
 long-lived nuclides:  3.22*10+04 Bq /day   MPE*  1,00*10+09  Bq /day 
 
 short-lived nuclides:  . Bq /day   MPE:  not regulated  Bq /day 
 
 Inert gases:  3.06*10+10 Bq /day   MPE:   4,60*10+13  Bq /day 
 
 Iodine:  4.49*10+04 Bq /day   MPE:   4,60*10+09  Bq /day 
 * - maximum permissible emission 
Water utilization
 
 on the town: 7434 m3 
 
 on construction yard: 0 m3 
 
 on industrial site: 0 m3 
 

2020-06-12

# 164

KhNPP 1
Electricity production
 
 per day: 21.23 mln.kW*h 
 
 since the beginning of month: 253.1 mln. kW*h 
 
 since the beginning of quarter: 1479.54 mln. kW*h 
 
 since the beginning of year: 1479.54 mln. kW*h 
 
 electricity utilization for auxiliaries: 5.15 % 
 
General characteristics
 
 
 Hours worked: 62.9 ef. days 
 
 Campaign: 356.6 ef. days 
 
 Performance factor (net)of the unit: 30.8 % 
 
 Electrical power (average daily): 884.76 MW 
 
 The temperature of circulating water at the inlet:  8.7  o, C 
 
KhNPP 2
Electricity production
 
 per day: 20.78 mln.kW*h 
 
 since the beginning of month: 238.16 mln. kW*h 
 
 since the beginning of quarter: 1326.37 mln. kW*h 
 
 since the beginning of year: 3539.21 mln. kW*h 
 
 electricity utilization for auxiliaries: 5.15 % 
 
General characteristics
 
 
 Hours worked: 197.2 ef. days 
 
 Campaign: 230 ef. days 
 
 Performance factor (net)of the unit: 30.2 % 
 
 Electrical power (average daily): 865.98 MW 
 
 The temperature of circulating water at the inlet:  8.2  o, C 
 
Operating mode of heating system
 
  direct  reverse  
 temperature : 7052 o, C 
 
 t of outside air: 26 o, C 
 
Emission in ventiduct
 
 long-lived nuclides:  3.22*10+04 Bq /day   MPE*  1,00*10+09  Bq /day 
 
 short-lived nuclides:  . Bq /day   MPE:  not regulated  Bq /day 
 
 Inert gases:  3.06*10+10 Bq /day   MPE:   4,60*10+13  Bq /day 
 
 Iodine:  3.22*10+04 Bq /day   MPE:   4,60*10+09  Bq /day 
 * - maximum permissible emission 
Water utilization
 
 on the town: 7493 m3 
 
 on construction yard: 61 m3 
 
 on industrial site: 455 m3 
 

2020-06-11

# 163

KhNPP 1
Electricity production
 
 per day: 21.26 mln.kW*h 
 
 since the beginning of month: 231.87 mln. kW*h 
 
 since the beginning of quarter: 1458.31 mln. kW*h 
 
 since the beginning of year: 1458.31 mln. kW*h 
 
 electricity utilization for auxiliaries: 5.03 % 
 
General characteristics
 
 
 Hours worked: 62 ef. days 
 
 Campaign: 356.6 ef. days 
 
 Performance factor (net)of the unit: 30.8 % 
 
 Electrical power (average daily): 885.66 MW 
 
 The temperature of circulating water at the inlet:  8.7  o, C 
 
KhNPP 2
Electricity production
 
 per day: 20.73 mln.kW*h 
 
 since the beginning of month: 217.38 mln. kW*h 
 
 since the beginning of quarter: 1305.59 mln. kW*h 
 
 since the beginning of year: 3518.42 mln. kW*h 
 
 electricity utilization for auxiliaries: 5.18 % 
 
General characteristics
 
 
 Hours worked: 196.3 ef. days 
 
 Campaign: 230 ef. days 
 
 Performance factor (net)of the unit: 30.2 % 
 
 Electrical power (average daily): 863.88 MW 
 
 The temperature of circulating water at the inlet:  8.2  o, C 
 
Operating mode of heating system
 
  direct  reverse  
 temperature : 7050 o, C 
 
 t of outside air: 24.2 o, C 
 
Emission in ventiduct
 
 long-lived nuclides:  3.07*10+04 Bq /day   MPE*  1,00*10+09  Bq /day 
 
 short-lived nuclides:  . Bq /day   MPE:  not regulated  Bq /day 
 
 Inert gases:  2.93*10+10 Bq /day   MPE:   4,60*10+13  Bq /day 
 
 Iodine:  3.07*10+04 Bq /day   MPE:   4,60*10+09  Bq /day 
 * - maximum permissible emission 
Water utilization
 
 on the town: 7445 m3 
 
 on construction yard: 40 m3 
 
 on industrial site: 451 m3 
 

2020-06-10

# 162

KhNPP 1
Electricity production
 
 per day: 21.17 mln.kW*h 
 
 since the beginning of month: 210.61 mln. kW*h 
 
 since the beginning of quarter: 1437.05 mln. kW*h 
 
 since the beginning of year: 1437.05 mln. kW*h 
 
 electricity utilization for auxiliaries: 4.96 % 
 
General characteristics
 
 
 Hours worked: 61.1 ef. days 
 
 Campaign: 356.6 ef. days 
 
 Performance factor (net)of the unit: 30.78 % 
 
 Electrical power (average daily): 881.94 MW 
 
 The temperature of circulating water at the inlet:  8.7  o, C 
 
KhNPP 2
Electricity production
 
 per day: 20.73 mln.kW*h 
 
 since the beginning of month: 196.64 mln. kW*h 
 
 since the beginning of quarter: 1284.85 mln. kW*h 
 
 since the beginning of year: 3497.69 mln. kW*h 
 
 electricity utilization for auxiliaries: 5.12 % 
 
General characteristics
 
 
 Hours worked: 195.4 ef. days 
 
 Campaign: 230 ef. days 
 
 Performance factor (net)of the unit: 30.23 % 
 
 Electrical power (average daily): 863.88 MW 
 
 The temperature of circulating water at the inlet:  8.2  o, C 
 
Operating mode of heating system
 
  direct  reverse  
 temperature : 7048 o, C 
 
 t of outside air: 21.2 o, C 
 
Emission in ventiduct
 
 long-lived nuclides:  3.27*10+04 Bq /day   MPE*  1,00*10+09  Bq /day 
 
 short-lived nuclides:  . Bq /day   MPE:  not regulated  Bq /day 
 
 Inert gases:  3.15*10+10 Bq /day   MPE:   4,60*10+13  Bq /day 
 
 Iodine:  3.27*10+04 Bq /day   MPE:   4,60*10+09  Bq /day 
 * - maximum permissible emission 
Water utilization
 
 on the town: 7552 m3 
 
 on construction yard: 36 m3 
 
 on industrial site: 421 m3 
 

2020-06-09

# 161

KhNPP 1
Electricity production
 
 per day: 21.18 mln.kW*h 
 
 since the beginning of month: 189.44 mln. kW*h 
 
 since the beginning of quarter: 1415.88 mln. kW*h 
 
 since the beginning of year: 1415.88 mln. kW*h 
 
 electricity utilization for auxiliaries: 4.95 % 
 
General characteristics
 
 
 Hours worked: 60.2 ef. days 
 
 Campaign: 356.6 ef. days 
 
 Performance factor (net)of the unit: 30.9 % 
 
 Electrical power (average daily): 882.54 MW 
 
 The temperature of circulating water at the inlet:  8.7  o, C 
 
KhNPP 2
Electricity production
 
 per day: 20.74 mln.kW*h 
 
 since the beginning of month: 175.91 mln. kW*h 
 
 since the beginning of quarter: 1264.12 mln. kW*h 
 
 since the beginning of year: 3476.96 mln. kW*h 
 
 electricity utilization for auxiliaries: 5.18 % 
 
General characteristics
 
 
 Hours worked: 194.5 ef. days 
 
 Campaign: 230 ef. days 
 
 Performance factor (net)of the unit: 30.4 % 
 
 Electrical power (average daily): 864.12 MW 
 
 The temperature of circulating water at the inlet:  8.2  o, C 
 
Operating mode of heating system
 
  direct  reverse  
 temperature : 7148 o, C 
 
 t of outside air: 23.1 o, C 
 
Emission in ventiduct
 
 long-lived nuclides:  3.26*10+04 Bq /day   MPE*  1,00*10+09  Bq /day 
 
 short-lived nuclides:  . Bq /day   MPE:  not regulated  Bq /day 
 
 Inert gases:  3.10*10+10 Bq /day   MPE:   4,60*10+13  Bq /day 
 
 Iodine:  3.26*10+04 Bq /day   MPE:   4,60*10+09  Bq /day 
 * - maximum permissible emission 
Water utilization
 
 on the town: 7181 m3 
 
 on construction yard: 17 m3 
 
 on industrial site: 266 m3 
 

2020-06-08

# 160

KhNPP 1
Electricity production
 
 per day: 21.09 mln.kW*h 
 
 since the beginning of month: 168.26 mln. kW*h 
 
 since the beginning of quarter: 1394.7 mln. kW*h 
 
 since the beginning of year: 1394.7 mln. kW*h 
 
 electricity utilization for auxiliaries: 4.97 % 
 
General characteristics
 
 
 Hours worked: 59.3 ef. days 
 
 Campaign: 356.6 ef. days 
 
 Performance factor (net)of the unit: 31.01 % 
 
 Electrical power (average daily): 878.64 MW 
 
 The temperature of circulating water at the inlet:  8.7  o, C 
 
KhNPP 2
Electricity production
 
 per day: 20.61 mln.kW*h 
 
 since the beginning of month: 155.17 mln. kW*h 
 
 since the beginning of quarter: 1243.38 mln. kW*h 
 
 since the beginning of year: 3456.22 mln. kW*h 
 
 electricity utilization for auxiliaries: 5.2 % 
 
General characteristics
 
 
 Hours worked: 193.6 ef. days 
 
 Campaign: 230 ef. days 
 
 Performance factor (net)of the unit: 30.45 % 
 
 Electrical power (average daily): 858.9 MW 
 
 The temperature of circulating water at the inlet:  8.2  o, C 
 
Operating mode of heating system
 
  direct  reverse  
 temperature : 7148 o, C 
 
 t of outside air: 22.9 o, C 
 
Emission in ventiduct
 
 long-lived nuclides:  3.25*10+04 Bq /day   MPE*  1,00*10+09  Bq /day 
 
 short-lived nuclides:  . Bq /day   MPE:  not regulated  Bq /day 
 
 Inert gases:  3.19*10+10 Bq /day   MPE:   4,60*10+13  Bq /day 
 
 Iodine:  3.25*10+04 Bq /day   MPE:   4,60*10+09  Bq /day 
 * - maximum permissible emission 
Water utilization
 
 on the town: 6591 m3 
 
 on construction yard: . m3 
 
 on industrial site: . m3 
 

2020-06-07

# 159

KhNPP 1
Electricity production
 
 per day: 21.02 mln.kW*h 
 
 since the beginning of month: 147.18 mln. kW*h 
 
 since the beginning of quarter: 1373.62 mln. kW*h 
 
 since the beginning of year: 1373.62 mln. kW*h 
 
 electricity utilization for auxiliaries: 4.94 % 
 
General characteristics
 
 
 Hours worked: 58.4 ef. days 
 
 Campaign: 356.6 ef. days 
 
 Performance factor (net)of the unit: 31 % 
 
 Electrical power (average daily): 875.82 MW 
 
 The temperature of circulating water at the inlet:  8.7  o, C 
 
KhNPP 2
Electricity production
 
 per day: 20.54 mln.kW*h 
 
 since the beginning of month: 134.56 mln. kW*h 
 
 since the beginning of quarter: 1222.77 mln. kW*h 
 
 since the beginning of year: 3435.61 mln. kW*h 
 
 electricity utilization for auxiliaries: 5.17 % 
 
General characteristics
 
 
 Hours worked: 192.7 ef. days 
 
 Campaign: 230 ef. days 
 
 Performance factor (net)of the unit: 30.6 % 
 
 Electrical power (average daily): 855.84 MW 
 
 The temperature of circulating water at the inlet:  8.2  o, C 
 
Operating mode of heating system
 
  direct  reverse  
 temperature : 7150 o, C 
 
 t of outside air: 23.8 o, C 
 
Emission in ventiduct
 
 long-lived nuclides:  3.25*10+04 Bq /day   MPE*  1,00*10+09  Bq /day 
 
 short-lived nuclides:  . Bq /day   MPE:  not regulated  Bq /day 
 
 Inert gases:  3.22*10+10 Bq /day   MPE:   4,60*10+13  Bq /day 
 
 Iodine:  3.25*10+04 Bq /day   MPE:   4,60*10+09  Bq /day 
 * - maximum permissible emission 
Water utilization
 
 on the town: 7544 m3 
 
 on construction yard: . m3 
 
 on industrial site: . m3 
 

2020-06-06

# 158

KhNPP 1
Electricity production
 
 per day: 21.09 mln.kW*h 
 
 since the beginning of month: 126.16 mln. kW*h 
 
 since the beginning of quarter: 1352.6 mln. kW*h 
 
 since the beginning of year: 1352.6 mln. kW*h 
 
 electricity utilization for auxiliaries: 5.01 % 
 
General characteristics
 
 
 Hours worked: 57.5 ef. days 
 
 Campaign: 356.6 ef. days 
 
 Performance factor (net)of the unit: 31.1 % 
 
 Electrical power (average daily): 878.7 MW 
 
 The temperature of circulating water at the inlet:  8.7  o, C 
 
KhNPP 2
Electricity production
 
 per day: 20.46 mln.kW*h 
 
 since the beginning of month: 114.02 mln. kW*h 
 
 since the beginning of quarter: 1202.23 mln. kW*h 
 
 since the beginning of year: 3415.07 mln. kW*h 
 
 electricity utilization for auxiliaries: 5.22 % 
 
General characteristics
 
 
 Hours worked: 191.8 ef. days 
 
 Campaign: 230 ef. days 
 
 Performance factor (net)of the unit: 30.5 % 
 
 Electrical power (average daily): 852.3 MW 
 
 The temperature of circulating water at the inlet:  8.2  o, C 
 
Operating mode of heating system
 
  direct  reverse  
 temperature : 7249 o, C 
 
 t of outside air: 21.6 o, C 
 
Emission in ventiduct
 
 long-lived nuclides:  3.25*10+04 Bq /day   MPE*  1,00*10+09  Bq /day 
 
 short-lived nuclides:  . Bq /day   MPE:  not regulated  Bq /day 
 
 Inert gases:  3.22*10+10 Bq /day   MPE:   4,60*10+13  Bq /day 
 
 Iodine:  3.25*10+04 Bq /day   MPE:   4,60*10+09  Bq /day 
 * - maximum permissible emission 
Water utilization
 
 on the town: 7252 m3 
 
 on construction yard: 0 m3 
 
 on industrial site: 0 m3 
 

2020-06-05

# 157

KhNPP 1
Electricity production
 
 per day: 21.06 mln.kW*h 
 
 since the beginning of month: 105.07 mln. kW*h 
 
 since the beginning of quarter: 1331.51 mln. kW*h 
 
 since the beginning of year: 1331.51 mln. kW*h 
 
 electricity utilization for auxiliaries: 4.97 % 
 
General characteristics
 
 
 Hours worked: 56.8 ef. days 
 
 Campaign: 356.6 ef. days 
 
 Performance factor (net)of the unit: 31.14 % 
 
 Electrical power (average daily): 877.44 MW 
 
 The temperature of circulating water at the inlet:  8.7  o, C 
 
KhNPP 2
Electricity production
 
 per day: 20.51 mln.kW*h 
 
 since the beginning of month: 93.56 mln. kW*h 
 
 since the beginning of quarter: 1181.77 mln. kW*h 
 
 since the beginning of year: 3394.61 mln. kW*h 
 
 electricity utilization for auxiliaries: 5.18 % 
 
General characteristics
 
 
 Hours worked: 191.1 ef. days 
 
 Campaign: 230 ef. days 
 
 Performance factor (net)of the unit: 30.64 % 
 
 Electrical power (average daily): 854.64 MW 
 
 The temperature of circulating water at the inlet:  8.2  o, C 
 
Operating mode of heating system
 
  direct  reverse  
 temperature : 7148 o, C 
 
 t of outside air: 18.1 o, C 
 
Emission in ventiduct
 
 long-lived nuclides:  3.28*10+04 Bq /day   MPE*  1,00*10+09  Bq /day 
 
 short-lived nuclides:  . Bq /day   MPE:  not regulated  Bq /day 
 
 Inert gases:  3.25*10+10 Bq /day   MPE:   4,60*10+13  Bq /day 
 
 Iodine:  3.28*10+04 Bq /day   MPE:   4,60*10+09  Bq /day 
 * - maximum permissible emission 
Water utilization
 
 on the town: 7421 m3 
 
 on construction yard: 37 m3 
 
 on industrial site: 379 m3 
 

2020-06-04

# 156

KhNPP 1
Electricity production
 
 per day: 20.98 mln.kW*h 
 
 since the beginning of month: 84.01 mln. kW*h 
 
 since the beginning of quarter: 1310.45 mln. kW*h 
 
 since the beginning of year: 1310.45 mln. kW*h 
 
 electricity utilization for auxiliaries: 4.98 % 
 
General characteristics
 
 
 Hours worked: 55.7 ef. days 
 
 Campaign: 356.6 ef. days 
 
 Performance factor (net)of the unit: 31.12 % 
 
 Electrical power (average daily): 874.2 MW 
 
 The temperature of circulating water at the inlet:  8.7  o, C 
 
KhNPP 2
Electricity production
 
 per day: 20.41 mln.kW*h 
 
 since the beginning of month: 73.05 mln. kW*h 
 
 since the beginning of quarter: 1161.26 mln. kW*h 
 
 since the beginning of year: 3374.1 mln. kW*h 
 
 electricity utilization for auxiliaries: 5.29 % 
 
General characteristics
 
 
 Hours worked: 190.1 ef. days 
 
 Campaign: 230 ef. days 
 
 Performance factor (net)of the unit: 30.33 % 
 
 Electrical power (average daily): 850.5 MW 
 
 The temperature of circulating water at the inlet:  8.2  o, C 
 
Operating mode of heating system
 
  direct  reverse  
 temperature : 7048 o, C 
 
 t of outside air: 13.5 o, C 
 
Emission in ventiduct
 
 long-lived nuclides:  3.27*10+04 Bq /day   MPE*  1,00*10+09  Bq /day 
 
 short-lived nuclides:  . Bq /day   MPE:  not regulated  Bq /day 
 
 Inert gases:  3.31*10+10 Bq /day   MPE:   4,60*10+13  Bq /day 
 
 Iodine:  4.89*10+04 Bq /day   MPE:   4,60*10+09  Bq /day 
 * - maximum permissible emission 
Water utilization
 
 on the town: 7484 m3 
 
 on construction yard: 43 m3 
 
 on industrial site: 351 m3 
 

2020-06-03

# 155

KhNPP 1
Electricity production
 
 per day: 20.93 mln.kW*h 
 
 since the beginning of month: 63.03 mln. kW*h 
 
 since the beginning of quarter: 1289.47 mln. kW*h 
 
 since the beginning of year: 1289.47 mln. kW*h 
 
 electricity utilization for auxiliaries: 4.96 % 
 
General characteristics
 
 
 Hours worked: 54.9 ef. days 
 
 Campaign: 356.6 ef. days 
 
 Performance factor (net)of the unit: 31.19 % 
 
 Electrical power (average daily): 872.28 MW 
 
 The temperature of circulating water at the inlet:  8.7  o, C 
 
KhNPP 2
Electricity production
 
 per day: 20.08 mln.kW*h 
 
 since the beginning of month: 52.64 mln. kW*h 
 
 since the beginning of quarter: 1140.85 mln. kW*h 
 
 since the beginning of year: 3353.69 mln. kW*h 
 
 electricity utilization for auxiliaries: 5.27 % 
 
General characteristics
 
 
 Hours worked: 189.2 ef. days 
 
 Campaign: 230 ef. days 
 
 Performance factor (net)of the unit: 30.66 % 
 
 Electrical power (average daily): 836.58 MW 
 
 The temperature of circulating water at the inlet:  8.2  o, C 
 
Operating mode of heating system
 
  direct  reverse  
 temperature : 7048 o, C 
 
 t of outside air: 10.4 o, C 
 
Emission in ventiduct
 
 long-lived nuclides:  3.13*10+04 Bq /day   MPE*  1,00*10+09  Bq /day 
 
 short-lived nuclides:  . Bq /day   MPE:  not regulated  Bq /day 
 
 Inert gases:  3.17*10+10 Bq /day   MPE:   4,60*10+13  Bq /day 
 
 Iodine:  4.79*10+04 Bq /day   MPE:   4,60*10+09  Bq /day 
 * - maximum permissible emission 
Water utilization
 
 on the town: 7442 m3 
 
 on construction yard: 20 m3 
 
 on industrial site: 350 m3 
 

2020-06-02

# 154

KhNPP 1
Electricity production
 
 per day: 21.07 mln.kW*h 
 
 since the beginning of month: 42.09 mln. kW*h 
 
 since the beginning of quarter: 1268.53 mln. kW*h 
 
 since the beginning of year: 1268.53 mln. kW*h 
 
 electricity utilization for auxiliaries: 4.99 % 
 
General characteristics
 
 
 Hours worked: 54 ef. days 
 
 Campaign: 356.6 ef. days 
 
 Performance factor (net)of the unit: 31.3 % 
 
 Electrical power (average daily): 878.1 MW 
 
 The temperature of circulating water at the inlet:  8.7  o, C 
 
KhNPP 2
Electricity production
 
 per day: 16.3 mln.kW*h 
 
 since the beginning of month: 32.56 mln. kW*h 
 
 since the beginning of quarter: 1120.77 mln. kW*h 
 
 since the beginning of year: 3333.61 mln. kW*h 
 
 electricity utilization for auxiliaries: 6.45 % 
 
General characteristics
 
 
 Hours worked: 188.3 ef. days 
 
 Campaign: 230 ef. days 
 
 Performance factor (net)of the unit: 29.1 % 
 
 Electrical power (average daily): 679.32 MW 
 
 The temperature of circulating water at the inlet:  8.2  o, C 
 
Operating mode of heating system
 
  direct  reverse  
 temperature : 6848 o, C 
 
 t of outside air: 8.9 o, C 
 
Emission in ventiduct
 
 long-lived nuclides:  3.20*10+04 Bq /day   MPE*  1,00*10+09  Bq /day 
 
 short-lived nuclides:  . Bq /day   MPE:  not regulated  Bq /day 
 
 Inert gases:  3.10*10+10 Bq /day   MPE:   4,60*10+13  Bq /day 
 
 Iodine:  6.06*10+04 Bq /day   MPE:   4,60*10+09  Bq /day 
 * - maximum permissible emission 
Water utilization
 
 on the town: 7479 m3 
 
 on construction yard: 10 m3 
 
 on industrial site: 341 m3 
 

2020-06-01

# 153

KhNPP 1
Electricity production
 
 per day: 21.02 mln.kW*h 
 
 since the beginning of month: 21.02 mln. kW*h 
 
 since the beginning of quarter: 1247.46 mln. kW*h 
 
 since the beginning of year: 1247.46 mln. kW*h 
 
 electricity utilization for auxiliaries: 4.98 % 
 
General characteristics
 
 
 Hours worked: 53.1 ef. days 
 
 Campaign: 356.6 ef. days 
 
 Performance factor (net)of the unit: 31.3 % 
 
 Electrical power (average daily): 875.76 MW 
 
 The temperature of circulating water at the inlet:  8.7  o, C 
 
KhNPP 2
Electricity production
 
 per day: 16.26 mln.kW*h 
 
 since the beginning of month: 16.26 mln. kW*h 
 
 since the beginning of quarter: 1104.47 mln. kW*h 
 
 since the beginning of year: 3317.3 mln. kW*h 
 
 electricity utilization for auxiliaries: 6.45 % 
 
General characteristics
 
 
 Hours worked: 187.6 ef. days 
 
 Campaign: 230 ef. days 
 
 Performance factor (net)of the unit: 29.1 % 
 
 Electrical power (average daily): 677.46 MW 
 
 The temperature of circulating water at the inlet:  8.2  o, C 
 
Operating mode of heating system
 
  direct  reverse  
 temperature : 7050 o, C 
 
 t of outside air: 11.8 o, C 
 
Emission in ventiduct
 
 long-lived nuclides:  3.22*10+04 Bq /day   MPE*  1,00*10+09  Bq /day 
 
 short-lived nuclides:  . Bq /day   MPE:  not regulated  Bq /day 
 
 Inert gases:  3.25*10+10 Bq /day   MPE:   4,60*10+13  Bq /day 
 
 Iodine:  4.18*10+04 Bq /day   MPE:   4,60*10+09  Bq /day 
 * - maximum permissible emission 
Water utilization
 
 on the town: 7371 m3 
 
 on construction yard: 1 m3 
 
 on industrial site: 211 m3